EPS-R960-I
Expanded Polystyrene
50 / 75 / 100 / 150 / 200 mm
960 / 1000 / 1150 mm
From 6.5 kg/m²
Class B1 / B2
Expanded polystyrene foam delivers solid insulation performance at the lowest cost per square metre. Closed-cell structure resists moisture and won’t sag, settle or compress under self-weight.
At 6.5 kg/m² (50 mm), EPS panels are the lightest option in our range — ideal where structural payload, transport cost or remote-site handling is a concern.
| Parameters | |
|---|---|
| مظهر السطح | كي الشريط · مسطح تمامًا |
| سماكة الفولاذ | 0.4 mm – 0.6 mm |
| كثافة اللب | 14 / 16 / 18 kg/m³ |
| Crest Height | 40 mm |
| السماكة الإجمالية | 50, 75, 100, 150, 200 mm |
| العرض الفعلي | 960 / 1000 / 1150 mm |
| Regular Colors | Off-white · Silver Gray · Sea Blue · Bright Red |
| Fire Treatment | B1 / B2 |
| Recommended Coating | PE, HDP, PVDF, SMP |
| Recommended Plate | Galvanized or Galvalume Plate |
| Recommended Manufacturer | Baosteel Group, Union Group, etc. |
| السماكة | U-Value |
|---|---|
| 50 mm | 0.66 W/m²K |
| 75 mm | 0.45 W/m²K |
| 100 mm | 0.34 W/m²K |
| 150 mm | 0.23 W/m²K |
| 200 mm | 0.17 W/m²K |
| Note: U-values calculated based on EPS thermal conductivity 0.033 W/m·K. Higher density grades available for premium thermal performance. | |
| العنصر | Unit | Actual Data | Industry Standard | Certification |
|---|---|---|---|---|
| Density | kg/m³ | 14 – 18 | > 12 | GB/T 6343 |
| Thermal Conductivity | W/m·K | < 0.033 | < 0.041 | GB/T 10294 |
| Combustion Performance | Class | B1 (self-extinguishing) | B1 | GB 8624 |
| Compressive Strength | kPa | > 100 | > 60 | GB/T 8813 |
| Bending Strength | kPa | > 150 | > 120 | GB/T 8812 |
| Water Absorption | % | < 4 | < 6 | GB/T 8810 |
| Dimensional Stability | % | < 0.3 | < 1 | GB/T 8811 |
Note: Calculations based on rockwool core density 100–140 kg/m³. L = Span (Unit: cm). Maximum allowable deflection per GB 50018 design code.
EPS-R960-II
Expanded Polystyrene
75 / 100 / 150 / 200 / 250 mm
1000 / 1150 mm
From 9.5 kg/m²
Class B1 / B2
Expanded polystyrene foam delivers solid insulation performance at the lowest cost per square metre. Closed-cell structure resists moisture and won’t sag, settle or compress under self-weight.
At 6.5 kg/m² (50 mm), EPS panels are the lightest option in our range — ideal where structural payload, transport cost or remote-site handling is a concern.
All Vikkins EPS panels use B1-grade FR-modified core. The foam is self-extinguishing on flame removal and will not sustain combustion — meets GB 8624 B1 and EN 13501 E classifications.
Recommended for non-public-occupancy buildings: warehouses, prefab housing, livestock and agricultural applications. For higher fire requirements, see our PU/PIR or Rockwool panels.
تتميز ألواح GWR بوجود مانع تسرب جانبي مدمج مصنوع من البولي يوريثان يغلق الحافة المقطوعة لقلب الصوف الزجاجي، مما يمنع تسرب الألياف وتسرب المياه وتلف الحواف أثناء التركيب — وهي ميزة أساسية مقارنة بألواح الصوف المعدني العادية.
Two stock profiles available — VK-GWR1 (single-step trapezoid) and VK-GWR2 (double-step low profile) — selected by aesthetics or required deflection.
| Parameters | |
|---|---|
| مظهر السطح | كي الشريط · مسطح تمامًا |
| سماكة الفولاذ | 0.5 mm – 0.8 mm |
| كثافة اللب | 20 / 22 / 25 kg/m³ |
| Crest Height | 40 mm |
| السماكة الإجمالية | 75, 100, 150, 200, 250 mm |
| العرض الفعلي | 1000 / 1150 mm |
| Regular Colors | Off-white · Silver Gray · Sea Blue · Bright Red |
| Fire Treatment | B1 / B2 |
| Recommended Coating | PE, HDP, PVDF, SMP |
| Recommended Plate | Galvanized or Galvalume Plate |
| Recommended Manufacturer | Baosteel Group, Union Group, etc. |
| السماكة | U-Value |
|---|---|
| 75 mm | 0.40 W/m²K |
| 100 mm | 0.30 W/m²K |
| 150 mm | 0.20 W/m²K |
| 200 mm | 0.15 W/m²K |
| 250 mm | 0.12 W/m²K |
| Note: U-values calculated based on EPS thermal conductivity 0.033 W/m·K. Higher density grades available for premium thermal performance. | |
| العنصر | Unit | Actual Data | Industry Standard | Certification |
|---|---|---|---|---|
| Density | kg/m³ | 20 – 25 | > 18 | GB/T 6343 |
| Thermal Conductivity | W/m·K | < 0.033 | < 0.041 | GB/T 10294 |
| Combustion Performance | Class | B1 (self-extinguishing) | B1 | GB 8624 |
| Compressive Strength | kPa | > 180 | > 100 | GB/T 8813 |
| Bending Strength | kPa | > 150 | > 120 | GB/T 8812 |
| Water Absorption | % | < 4 | < 6 | GB/T 8810 |
| Dimensional Stability | % | < 0.3 | < 1 | GB/T 8811 |
Note: Calculations based on glass wool core density 48–80 kg/m³. L = Span (Unit: cm). Maximum allowable deflection per GB 50018 design code.
EPS-R960-III
Expanded Polystyrene
50 / 75 / 100 mm
950 / 1150 mm
From 5.2 kg/m²
Class B1 / B2
Expanded polystyrene foam delivers solid insulation performance at the lowest cost per square metre. Closed-cell structure resists moisture and won’t sag, settle or compress under self-weight.
At 6.5 kg/m² (50 mm), EPS panels are the lightest option in our range — ideal where structural payload, transport cost or remote-site handling is a concern.
All Vikkins EPS panels use B1-grade FR-modified core. The foam is self-extinguishing on flame removal and will not sustain combustion — meets GB 8624 B1 and EN 13501 E classifications.
Recommended for non-public-occupancy buildings: warehouses, prefab housing, livestock and agricultural applications. For higher fire requirements, see our PU/PIR or Rockwool panels.
| Parameters | |
|---|---|
| مظهر السطح | كي الشريط · مسطح تمامًا |
| سماكة الفولاذ | 0.3 mm – 0.5 mm |
| كثافة اللب | 10 / 12 / 14 kg/m³ |
| Crest Height | 40 mm |
| السماكة الإجمالية | 50, 75, 100 mm |
| العرض الفعلي | 950 / 1150 mm |
| Regular Colors | Off-white · Silver Gray · Sea Blue · Bright Red |
| Fire Treatment | B1 / B2 |
| Recommended Coating | PE, HDP, PVDF, SMP |
| Recommended Plate | Galvanized or Galvalume Plate |
| Recommended Manufacturer | Baosteel Group, Union Group, etc. |
| السماكة | U-Value |
|---|---|
| 50 mm | 0.72 W/m²K |
| 75 mm | 0.50 W/m²K |
| 100 mm | 0.38 W/m²K |
| Note: U-values calculated based on EPS thermal conductivity 0.033 W/m·K. Higher density grades available for premium thermal performance. | |
| العنصر | Unit | Actual Data | Industry Standard | Certification |
|---|---|---|---|---|
| Density | kg/m³ | 10 – 14 | > 8 | GB/T 6343 |
| Thermal Conductivity | W/m·K | < 0.033 | < 0.041 | GB/T 10294 |
| Combustion Performance | Class | B1 (self-extinguishing) | B1 | GB 8624 |
| Compressive Strength | kPa | > 70 | > 50 | GB/T 8813 |
| Bending Strength | kPa | > 150 | > 120 | GB/T 8812 |
| Water Absorption | % | < 4 | < 6 | GB/T 8810 |
| Dimensional Stability | % | < 0.3 | < 1 | GB/T 8811 |
Note: Calculations based on glass wool core density 48–80 kg/m³. L = Span (Unit: cm). Maximum allowable deflection per GB 50018 design code.